StageV Version

Machine controls (1)

Machine controls (1)

 

  1. Red light: when on, indicates a malfunction of the alternator;
  2. Red light: when on during engine operation, indicates low engine oil pressure; after a defined time, the CPU turns off the engine;
  3. Red light: when on during engine operation, indicates that the engine air intake filter or compressor air filter is clogged; after a defined time, the CPU turns off the engine;
  4. Red light: when on during engine operation, indicates an engine fault; after a defined time, the CPU turns off the engine (only for machines with StageV);
  5. Yellow light: when on, means that the glow plug preheating is active. When off, the engine can be started;
  6. Red light: when on during engine operation, indicates a high coolant temperature; after a defined time, the CPU turns off the engine;
  7. Red light: when on during compressor operation, indicates low compressor oil pressure; after a defined time, the CPU turns off the engine;
  8. Yellow light: turns on if the fuel reserve is activated.

     
  9. Display;
  10. Ignition key;
  11. Engine start/stop button (red light in the center of the button: lights up if the engine starts);
  12. Two-position stable selector:
    - to the left: allows you to perform a manual material transport cycle;
    - to the right: allows you to perform, in automatic mode, a material transport cycle;
  13. USB port;
  14. Two-position stable selector:
    - to the left: turns off the work light;
    - to the right: turns on the work light;
  15. Analog hour meter: indicates the number of engine operating hours.

 

Machine description (1)

Machine description (1)

 

  1. Air pressure gauge
    Indicates the hydraulic pressure of the mixing tank;
     
  2. Oil pressure gauge
    Indicates the hydraulic pressure of the hydraulic circuit;
     
  3. Compressor air pressure gauge
    Indicates the hydraulic pressure of the compressor;
     
  4. Mixer control lever
    Three-position lever:
    - Up (stable) - mixer rotates clockwise;
    - Center - Neutral;
    - Down (not stable) - mixer rotates counterclockwise;
     
  5. Pressure washer lever
     
  6. Bucket control lever
    Three-position lever:
    - Up (not stable) - bucket is raised;
    - Center - Neutral;
    - Down (not stable) - bucket is lowered.

 

Machine description (2)

Machine description (2)

 

  1. Automatic pumping cycle start
     
  2. Air regulation valve
    Air flow regulation to the mixing chamber and material discharge manifold:
    - Upward - gradual regulation of incoming air;
    - Central - neutral;
    - Downward - gradual regulation of outgoing air;
     
  3. General air tap
    Dedicated to sending air to the tank or service tap;
     
  4. Service air tap
    Auxiliary air intake.