Starting in endothermic mode
Starting in endothermic mode (1)
- Connect the battery by rotating the battery switch located inside the engine compartment;
- Make sure the protective cap of the socket is inserted.
Starting in endothermic mode (2)
To power up and start the TSR7 with internal combustion engine:
- Make sure that the mains power supply is not active or that the power cable is disconnected;
- Make sure that the red emergency buttons are not pressed (otherwise, reset);
- Insert the key into the key selector on the control panel.
Starting in endothermic mode (3)
- Turn the key selector to the first (stable) position to power the machine's CPU;
- The console keys will light up in quick sequence to indicate the start-up status;
- Make sure that, after a few seconds during which the CPU performs its start-up and control procedures, the battery power light is on (1).
Staring in endothermic mode (4)
- Press the button (7) and hold it down for more than two seconds, so as to activate the glow plugs.
- The button light turns on with a fixed blue light to indicate that the glow plugs have been turned on.
The corresponding yellow light (S1) on the dashboard also turns on during this phase
Starting in endothermic mode (5)
- Release the engine start button after sufficient time has elapsed for the engine to preheat;
- When the button is released or after 15 seconds have elapsed, the button light turns red and at the same time the starter motor starts to rotate;
- The starter motor remains activated until the engine starts.
When the engine is running, the start button light stays red.
Starting in endothermic mode (6)
-
When the diesel engine is on, pressing the start button will turn it off.
For safety reasons, after switching off, the diesel engine cannot be restarted before five seconds have passed;
- When the diesel engine is switched off, the red light on the start button (7) goes off.