Usage notes

Usage notes (1)

Usage notes (1)
 
To use the machine as a mixer and pump (automatic mode):
  • The service tap (18) must be closed and the service lever (22) must be set to ON;
  • Start the machine by turning the key (19) to the ON position, wait for the glow plug LED (20) to turn off; then start the engine by pressing the green START button (21);
  • To start the pumping cycle, the selector (23) must be set to AUTO;
  • Press the START button on the right of the machine to start the automatic pumping cycle, then adjust the amount of air between the tank and the delivery manifold with the lever on the right of the machine;
  • At the end of the cycle, pumping will stop automatically, after which it will be possible to open the tank and add more material.

 

Usage notes (2)

Usage notes (2)
 
To use the machine only as a compressor:
  • Connect the tap (18) with the tool to be used;
  • Start the machine by turning the key (19) to the ON position; then wait for the glow plug LED (20) to go off and start the engine by pressing the START button (21);
  • Set the selector (23) to the man position;
  • The pressure gauge (24) indicates the pressure of the air supplied to the service tap;
  • Now it is possible to use the service tap for accessory equipment by opening the tap;
  • Before switching off the engine, the selector (23) must be set to AUTO.

 

Usage notes (3)

Usage notes (3)
Coupling joints
 
Perrot couplings
  • When connecting the pipes, check that the rubber ring (26) is fitted. Lock the levers firmly with the safety pin (27);
  • Pipes ø65x84 (length of 10 or 20 metres) for a maximum pumpable grain size of 0-15mm.
*Always check that the joints are clean and properly locked
 

Usage notes (4)

Usage notes (4)
Coupling joints
 
Camlock couplings
  • When connecting hoses with Camlock fitting, ensure that the rubber ring (25) is fitted, then lock the levers firmly.
*Always ensure that the couplings are clean and properly locked
 

Usage notes (5)

Usage notes (5)
Coupling joints
 
Victaulic couplings
  • When connecting the hoses, check that the rubber gasket (28) is mounted, lock the lever firmly;
  • Hoses ø90 (length 10 meters) for maximum pumpable grain size 0-25mm.
*Always check that the joints are clean and properly locked
 

Usage notes (6)

Usage notes (6)
In the DCB/P version
  • Remember to connect the electric cable and the scraper pulling cable